Determination of Carbon in Steel Sheets of Ultra-Low Carbon Content by Direct-Reading Atomic Emission Spectrography

Jian Li
2014-01-01
Abstract:A set of CRM′s with values of wC%ranged from 0.002%to 0.03% was analyzed for their carbon contents with a direct reading AES under the specified working conditions.A statistical study was made based on data obtained,i.e.,the values of wC% of each of the CRM′s and their statistics and levels of accuracy and precision of the method for determination of ultra-low carbon in steel sheets were assessed.It was shown that:1accuracy of the analytical results was affected by the matrix background of individual sample and standardization condition of the instrument,it is advised to choose CRM′s having similar composition with the sample for calibration of instrument and rational condition of standardization;2in the range of carbon content concerned,only small differences among values of S%(either for n=5or 10)were obtained with difference of extreme values of 3×10-4%,but significant differences of values of RSD% were observed with min.and max.values of 2%and 21%respectively;and3range of fluctuation of systematic error(or of accuracy)for determination of carbon content at the magnitude of 10-5attained to values ranged in ±1×10-4%.
What problem does this paper attempt to address?