A New Compensation Method for Current Reference of Active Power Filters

Shengwei Mei
2008-01-01
Abstract:As a dynamic harmonic filtering equipment,the active power filter(APF) is asked to have a very fast response to the compensated signal.However,the process of data collection,arithmetic calculation and PWM bring time delay more or less.Obviously,the time delay has a negative impact to the overall performance of an APF.To alleviate the influence of time delay in APF,this paper sets up a transfer function for the APF control system,in which time delays introduced by different processes are considered.The frequency response of the transfer function is analyzed in MATLAB.The fact that both the magnitude and phase of the current reference are distorted is revealed.Besides,it is observed that the system voltage at the link point has significant influence to the current reference.Based on the analysis,a new method to compensate the time delay of APF control system is proposed,which modifies both the phase and magnitude of the current reference while it also takes into account the influence of system voltage.Experiment results validate the necessity of the modification and demonstrate the effectiveness and efficiency of the proposed method.