Treatment of High-Concentration Na_2SO_4 and CaCl_2 Wastewaters by Vacuum Membrane Distillation

XU Zhen-liang,D Lab
2013-01-01
Abstract:Using polytetrafluoroethylene(PTFE)flat membrane with the mean pore size of 0.1μm,the high-concentration Na 2 SO 4 and CaCl 2 wastewater was treated by vacuum membrane distillation(VMD).The effects of operating conditions such as permeate pressure,feed temperature and feed concentration on the permeate flux and rejection were investigated.The experimental results showed that with increasing feed temperature and reducing permeate pressure,the permeate flux increased.The effects of feed temperatures on permeate flux was significant.The permeate flux was increased about 4.5times with the feed temperature increasing from 323.15Kto 343.15K.In addition,the effects of feed concentrations on the permeate flux were slightly.At the same time,all the rejections of VMD were as high as 99.99%.
What problem does this paper attempt to address?