Diagnostic Value of Rest and Stress Gated 82rb PET Myocardial Perfusion Imaging Using Quantitative Software

Raghuveer K.Halkar,Cesar A.Santana
DOI: https://doi.org/10.3760/cma.j.issn.2095-2848.2008.05.015
2008-01-01
Abstract:Objective Gated myocardial perfusion imaging (MPI) is regularly performed using SPECT. More recently, gated 82Rb MPI has been used to assess left ventricular myocardial perfusion and function with new generation PET scanners. The objective of this study was to evaluate the value of rest and stress gated 82 Rb PET myocardial perfusion imaging and to determine whether the quantitative technique increased the confidence level of the interpreters. Methods Thirty-two patients underwent rest and adenosine stress gated 82Rb PET MPI. Emory Cardiac Toolbox quantitative software was used for processing and interpretation. Left ventricular ejection fraction (LVEF), end-diastolic, end-systolic and transient ischemia dilation ratio were automatically generated. Three interpreters (nuclear medicine doctors) independently reviewed the studies. Visual scoring (1 - 5 scales : excellent, good, unsure, poor, uninterpretable) was used to assess the overall quality of the gated images and the added confidence level of interpretation. Visual assessment of the LVEF was compared to the automatically generated LVEF. Comparison between the visual assessment and software generated was graded on a 1- 5 scales (helpful, probably helpful, unsure, probably not helpful, definitely not helpful). The analysed items were divided into two groups (favorable group and negative group). The percentage and 95% confidence intervals of each group were calculated. Results A total of 192 gated studies were evaluated (64 gated × 3 interpreters). The overall quality of the gated images was good [excellent 40.1% (77/192) , good 43.2% (83/192), unsure 3.1% (6/192), poor 13.6% (26/192), uninterpretable 0]. The 95% confidence intervals of good and excellent quality range from 78.1% to 88.6%. The interpreters agreed with the automated LVEF on 85.4% of the gated images [agree 76.6% (147/192), probably agree 8.8% (17/192), unsure 3.1% (6/192), probably disagree 8. 8% (17/192), disagree 2.6% (5/192)]. And its 95% confidence intervals range from 80.4% to 90. 4%. Moreover, the functional information provided additional confidence for image interpretation [helpful 25.0% (48/192), probably helpful 28. 1% (54/192), unsure 2.6% (5/192), probably not helpful 15.1% (29/192), definitely not helpful 29.2% (59/192)]. The 95% confidence intervals of regarding the functional information as helpful and probably helpful range from 46.1% to 60.2%. Conclusion Rest and stress gated sz Rb PET myocardial perfusion imaging and quantitative software are helpful to the interpreters in their diagnosis of coronary artery disease.
What problem does this paper attempt to address?