Response to Letter from Yamada and Kay Regarding Article, “ventricular Arrhythmias Arising from the Left Ventricular Outflow Tract below the Aortic Sinus Cusps: Mapping and Catheter Ablation Via Transseptal Approach and Electrocardiographic Characteristics” by Ouyang Et Al

Feifan Ouyang,Shibu Mathew,Shulin Wu,Masashi Kamioka,Andreas Metzner,Yan Xue,Weizhu Ju,Bing Yang,Xianzhang Zhan,Andreas Rillig,Tina Lin,Peter Rausch,Sebastian Deiß,Christine Lemeš,Tobias Tönnis,Erik Wißner,Roland Richard Tilz,Karl‐Heinz Kück,Minglong Chen
DOI: https://doi.org/10.1161/circep.114.002219
2014-01-01
Circulation Arrhythmia and Electrophysiology
Abstract:HomeCirculation: Arrhythmia and ElectrophysiologyVol. 7, No. 5Response to Letter from Yamada and Kay Regarding Article, "Ventricular Arrhythmias Arising From the Left Ventricular Outflow Tract Below the Aortic Sinus Cusps: Mapping and Catheter Ablation via Transseptal Approach and Electrocardiographic Characteristics" by Ouyang et al Free AccessLetterPDF/EPUBAboutView PDFView EPUBSections ToolsAdd to favoritesDownload citationsTrack citationsPermissions ShareShare onFacebookTwitterLinked InMendeleyReddit Jump toFree AccessLetterPDF/EPUBResponse to Letter from Yamada and Kay Regarding Article, "Ventricular Arrhythmias Arising From the Left Ventricular Outflow Tract Below the Aortic Sinus Cusps: Mapping and Catheter Ablation via Transseptal Approach and Electrocardiographic Characteristics" by Ouyang et al Feifan Ouyang, MD and Shibu Mathew, MD Shulin Wu, MD Masashi Kamioka, MD and Andreas Metzner, MD Yumei Xue, MD Weizhu Ju, MD and Bing Yang, MD Xianzhang Zhan, MD Andreas Rillig, MD, Tina Lin, MD, Peter Rausch, MD, Sebastian Deiß, MD, Christine Lemes, MD, Tobias Tönnis, MD, Erik Wissner, MD, Roland Richard Tilz, MD and Karl-Heinz Kuck, MD Minglong Chen, MD Feifan OuyangFeifan Ouyang Department of Cardiology Askepios Klinik St. Georg, Hamburg, Germany and Shibu MathewShibu Mathew Department of Cardiology Askepios Klinik St. Georg, Hamburg, Germany Shulin WuShulin Wu Department of Cardiology, Guangdong Cardiovascular Institute and Guangdong Provincal People's Hospital, Guangzhou, China Masashi KamiokaMasashi Kamioka Department of Cardiology Askepios Klinik St. Georg, Hamburg, Germany and Andreas MetznerAndreas Metzner Department of Cardiology Askepios Klinik St. Georg, Hamburg, Germany Yumei XueYumei Xue Department of Cardiology, Guangdong Cardiovascular Institute and Guangdong Provincal People's Hospital, Guangzhou, China Weizhu JuWeizhu Ju Department of Cardiology, The 1st Affiliated Hospital of Nanjing Medical University, Nanjing, China and Bing YangBing Yang Department of Cardiology, The 1st Affiliated Hospital of Nanjing Medical University, Nanjing, China Xianzhang ZhanXianzhang Zhan Department of Cardiology, Guangdong Cardiovascular Institute and Guangdong Provincal People's Hospital, Guangzhou, China Andreas RilligAndreas Rillig Department of Cardiology Askepios Klinik St. Georg, Hamburg, Germany , Tina LinTina Lin Department of Cardiology Askepios Klinik St. Georg, Hamburg, Germany , Peter RauschPeter Rausch Department of Cardiology Askepios Klinik St. Georg, Hamburg, Germany , Sebastian DeißSebastian Deiß Department of Cardiology Askepios Klinik St. Georg, Hamburg, Germany , Christine LemesChristine Lemes Department of Cardiology Askepios Klinik St. Georg, Hamburg, Germany , Tobias TönnisTobias Tönnis Department of Cardiology Askepios Klinik St. Georg, Hamburg, Germany , Erik WissnerErik Wissner Department of Cardiology Askepios Klinik St. Georg, Hamburg, Germany , Roland Richard TilzRoland Richard Tilz Department of Cardiology Askepios Klinik St. Georg, Hamburg, Germany and Karl-Heinz KuckKarl-Heinz Kuck Department of Cardiology Askepios Klinik St. Georg, Hamburg, Germany Minglong ChenMinglong Chen Department of Cardiology, The 1st Affiliated Hospital of Nanjing Medical University, Nanjing, China Originally published1 Oct 2014https://doi.org/10.1161/CIRCEP.114.002219Circulation: Arrhythmia and Electrophysiology. 2014;7:994We thank Drs Yamada and Kay for their comments regarding our article "Ventricular arrhythmias arising from the left ventricular outflow tract below the aortic sinus cusps: mapping and catheter ablation via transseptal approach and electrocardiographic characteristics."1 The main issues raised by Drs Yamada and Kay focused around the transseptal approach used in our study to obtain better access to the area termed the LV summit.We agree with the authors that using the retrograde aortic approach and with the catheter inversion technique, some of the regions beneath the aortic sinus cusps (ASC) can be reached. However, when this is performed with the 3D mapping system, one can see that in the majority of the time, there is a distance between the left ventricular and the aorta maps. Given that the aortic valves are only millimeters thin, this suggests that the left ventricular map beneath the ASCs is not complete. This is likely because mapping with a looped mapping catheter from the retrograde aortic approach is dependent on the diameter of the aorta, the aortic valves themselves, and the left ventricular dimensions. When the ventricular arrythmias (VA) originate from an area further away from the ASCs, this does not pose a problem and ablation may be successful. However, when the origin of the VA is just below and near to the ASCs, in our experience this becomes difficult to ablate and achieve success. We have found that this area is best reached via the transseptal approach, and the left ventricular map abuts the aorta map during 3D-mapping with this approach. Addtionally in our study, the VAs could only be ablated via the transseptal approach in 6 patients who had undergone previous failed ablation with catheter inversion techniques via transaortic approach.Furthermore, we agree with the comment that mapping within the ASCs should be initially performed via the retrograde aortic approach. Because of the close anatomic relationship of the structures in this area, the ECG characteristics of VAs originating from above or below the ASCs are similar with great overlap. In a recent study, we found that the absence of prepotentials at the earliest site in the aortic sinus of Valsalva during VAs and a bigger aVL:aVR ratio >1.45 strongly indicates a VA origin from below the ASC.2Finally, although a transseptal puncture at the anteroinferior fosa ovalis is not always safe, all transseptal punctures in this study were performed by highly experienced operators and guided by an ablation catheter placed in the noncoronary ASC. This outlines the anatomic location of the posterior wall of the aorta and minimizes the complication risk. In addition, it is our institutional standard that during such cases, the transseptal puncture is performed with an ACT >250 ms.Feifan Ouyang, MDShibu Mathew, MDDepartment of CardiologyAskepios Klinik St. GeorgHamburg, GermanyShulin Wu, MDDepartment of CardiologyGuangdong Cardiovascular Institute and Guangdong ProvincalPeople's HospitalGuangzhou, ChinaMasashi Kamioka, MDAndreas Metzner, MDDepartment of CardiologyAskepios Klinik St. GeorgHamburg, GermanyYumei Xue, MDDepartment of CardiologyGuangdong Cardiovascular Institute and Guangdong ProvincalPeople's HospitalGuangzhou, ChinaWeizhu Ju, MDBing Yang, MDDepartment of CardiologyThe 1st Affiliated Hospital of Nanjing Medical UniversityNanjing, ChinaXianzhang Zhan, MDDepartment of CardiologyGuangdong Cardiovascular Institute and Guangdong ProvincalPeople's HospitalGuangzhou, ChinaAndreas Rillig, MDTina Lin, MDPeter Rausch, MDSebastian Deiß, MDChristine Lemes, MDTobias Tönnis, MDErik Wissner, MDRoland Richard Tilz, MDKarl-Heinz Kuck, MDDepartment of CardiologyAskepios Klinik St. GeorgHamburg, GermanyMinglong Chen, MDDepartment of CardiologyThe 1st Affiliated Hospital of Nanjing Medical UniversityNanjing, ChinaDisclosuresNone.References1. Ouyang F, Mathew S, Wu S, Kamioka M, Metzner A, Xue Y, Ju W, Yang B, Zhan X, Rillig A, Lin T, Rausch P, Deiß S, Lemes C, Tönnis T, Wissner E, Tilz RR, Kuck KH, Chen M. Ventricular arrhythmias arising from the left ventricular outflow tract below the aortic sinus cusps: mapping and catheter ablation via transseptal approach and electrocardiographic characteristics.Circ Arrhythm Electrophysiol. 2014; 7:445–455.LinkGoogle Scholar2. Kamioka M, Mathew S, Metzner A, Rillig A, Deiss S, Rausch P, Leme C, Lin T, Bucur T, Tilz RR, Wissner E, Kuck K-H, Ouyang F. Electrocardiographic and electrophysiological predictors of ventricular arrhythmias originating from the left ventricular outflow tract above and below the aortic valve.HRS Annual Scientific Sessions; 2014.Google Scholar Previous Back to top Next FiguresReferencesRelatedDetailsCited By Heeger C, Hayashi K, Kuck K and Ouyang F (2016) Catheter Ablation of Idiopathic Ventricular Arrhythmias Arising From the Cardiac Outflow Tracts – Recent Insights and Techniques for the Successful Treatment of Common and Challenging Cases –, Circulation Journal, 10.1253/circj.CJ-16-0293, 80:5, (1073-1086), . October 2014Vol 7, Issue 5 Advertisement Article InformationMetrics © 2014 American Heart Association, Inc.https://doi.org/10.1161/CIRCEP.114.002219PMID: 25336377 Originally publishedOctober 1, 2014 PDF download Advertisement SubjectsArrhythmiasCatheter Ablation and Implantable Cardioverter-DefibrillatorElectrophysiology
What problem does this paper attempt to address?