A Comparison Study on the Microleakage of Glass-Ionomer Cements of Teeth by Confocal Laser Scanning Microscope and Metallurgical Microscope

Hong Kang
2011-01-01
Abstract:Objective:To evaluate and compare two kinds of microscopes used to measure the microleakage of glass-ionomer cements in isolated human teeth.Methods: Extracted caries-free premolars were selected and the standard class Ⅰ cavities were prepared on occlusal surface of the teeth and filled with glass-ionomer cements(group A1 and B1) and resin-modified glass-ionomer cements(group A2 and B2)respectively.The samples were kept in 0.1% rhodamine-B solution or 1% methylene blue at 37 ℃ for 24 hours.Confocal laser scanning microscope(CLSM) or metallurgical microscope were used to visualize the depths of dye penetrated pathways and quantitate the depth of penetration respectively.Results:The dye penetrations existed in all of the groups.The microleakage depths of observed by CLSM(22.57 ± 2.59) μm and(21.93 ± 1.51) μm were resulted in less marginal microleakage than metallurgical microscope(33.18 ± 5.59)μm and(32.30 ± 3.76) μm,P 0.05.The microleakage depths measured under CLSM and metallugical microscope had significant differences.Conclusion: CLSM is a preferred way in evaluation of microleakage glass-ionomer cements or resin-modified glass-ionomer cements comparing with metallurgical microscope.
What problem does this paper attempt to address?