Quantitative Evaluation of Brazed Joints in Flat Structure with Ultrasonic Inspection Method

Jing Liang,Yiwei Shi,Yang Dang-gang
2008-01-01
Abstract:_ _ Abstract This paper describes the method to evaluate the brazed join ts quantitatively through the ultrasonic C-scan images defined as three types that are overall area, localized area a nd honeycomb. For each type of joint, different way is suggested to dist inguish the defects. The software used to calculate the overall area of the brazed joint (S1) a nd the area of the defects (S2) is developed. On the other hand, the influence of the testing parameters on the C-scan images is investigated to establish the inspection specification to assure the consistency a nd authenticity of the results. It is concluded that using small focus transducer focused on the brazed joi nts leads to optimum images and the sensitivity for C-scan should be set with the artific ial defect. Keyword : brazed joint, C-scan, ultrasonic inspection, quantitative evaluation 1. Instruction The evaluation index of the quality of the brazed joints used commonly is the defect area or the proportion of the good area in the brazed joints. If the overall area of the joints is S 1 and the area of the defects is S 2, the proportion of good area in the brazed joints (Q) m ay be calculated in the formula below:
What problem does this paper attempt to address?