Performance Analysis of A Steam Ejector for A Steam Eject Refrigeration System

Li Dongzhe,Zhou Feng,Ma Guoyuan,Zhao Yaqian,Yan Xianghui
DOI: https://doi.org/10.3969/j.issn.1671-6612.2023.02.014
2023-01-01
Abstract:The steam jet refrigeration system charged with natural working fluid can utilize the low-grade waste heat effectively, but the system performance still depends on the steam ejector as the key component. The ideal gas model was adopted in most investigations, which cannot reflect the real working situation in the steam ejector. A new wet steam model for a steam ejector was built up in this paper. The effects on the entrainment ratio of the steam ejector from fluid parameters were analyzed and the two different models were compared. The results show that the entrainment ratio of the wet steam model is 6.92% higher than that of the ideal gas model. The critical pressure point exists in the ejector, and the entrainment ratio decreases with the increasing fluid outlet pressure beyond the critical pressure point. The entrainment ratio first increases and then decreases with the increasing inlet pressure, and there is an optimal steam inlet pressure point. When the primary steam inlet pressure increases the entrainment ratio increases. The entrainment ratio of the ejector increases with the increasing superheat level of the primary steam inlet, but changes little with the increasing superheat level of the ejected steam.
What problem does this paper attempt to address?