Case Study for Enhancing Concentration of Waste Dilute Sulfuric Acid by Microwave Flash Evaporation: Modelling, Heat Transfer, Energy Consumption and Process Optimization

Shihong Tian,Lei Guo,Shaohua Ju,Wei Li,Lei Xu,Linqing Dai
DOI: https://doi.org/10.1016/j.seppur.2023.123930
IF: 8.6
2023-01-01
Separation and Purification Technology
Abstract:The ameliorative microwave flash evaporation system (MFE) was utilized to concentrate and distillate waste sulfuric acid, the system may overcome the problems of equipment corrosion, product pollution, high energy consumption, long process flow, and low heat transfer rate during recovery process of waste sulfuric acid. The dilute sulfuric acid with mass fraction of 75 wt% was used as experimental medium, 5 experimental cases was generated to verify the effects of MFE with the conditions of different volume, microwave power and depres-surization rate. Experimental results demonstrated that the sulfuric acid could be concentrated to mass fraction of 85-95%, and the heating efficiency was among 30% to 80%, heat transfer volume coefficient was among 100 J/K.L-1 to 500 J/K.L-1 with the combination of vacuum and microwave heating during flash evaporation process. Thermal process analysis indicated that the interaction among experimental factors affected concentration and distillation process. At last, we gave the modeling and process optimization method for concentrating sulfuric acid through MFE process based on analyzing those experimental cases.
What problem does this paper attempt to address?