SWCNTs/PEDOT:PSS-Modified Microelectrode Arrays for Dual-Mode Detection of Electrophysiological Signals and Dopamine Concentration in the Striatum under Isoflurane Anesthesia
Enhui He,Shengwei Xu,Yuchuan Dai,Yiding Wang,Guihua Xiao,Jingyu Xie,Shihong Xu,Penghui Fan,Fan Mo,Mixia Wang,Yilin Song,Huabing Yin,Yinghui Li,Ying Wang,Xinxia Cai
DOI: https://doi.org/10.1021/acssensors.1c01241
IF: 8.9
2021-08-19
ACS Sensors
Abstract:Accurate detection of the degree of isoflurane anesthesia during a surgery is important to avoid the risk of overdose isoflurane anesthesia timely. To address this challenge, a four-shank implantable microelectrode array (MEA) was fabricated for the synchronous real-time detection of dual-mode signals [electrophysiological signal and dopamine (DA) concentration] in rat striatum. The SWCNTs/PEDOT:PSS nanocomposites were modified onto the MEAs, which significantly improved the electrical and electrochemical performances of the MEAs. The electrical performance of the modified MEAs with a low impedance (16.20 ± 1.68 kΩ) and a small phase delay (−27.76 ± 0.82°) enabled the MEAs to detect spike firing with a high signal-to-noise ratio (> 3). The electrochemical performance of the modified MEAs with a low oxidation potential (160 mV), a low detection limit (10 nM), high sensitivity (217 pA/μM), and a wide linear range (10 nM–72 μM) met the specific requirements for DA detection in vivo. The anesthetic effect of isoflurane was mediated by inhibiting the spike firing of D2_SPNs (spiny projection neurons expressing the D2-type DA receptor) and the broadband oscillation rhythm of the local field potential (LFP). Therefore, the spike firing rate of D2_SPNs and the power of LFP could reflect the degree of isoflurane anesthesia together. During the isoflurane anesthesia-induced death procedure, we found that electrophysiological activities and DA release were strongly inhibited, and changes in the DA concentration provided more details regarding this procedure. The dual-mode recording MEA provided a detection method for the degree of isoflurane anesthesia and a prediction method for fatal overdose isoflurane anesthesia.The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acssensors.1c01241.Materials and methods, recording equipment , implantation position of the MEA, experimental procedure, comparison of the active surface area and stability of SWCNTs/PEDOT:PSS nanocomposites, comparison of typical electrophysiology patterns, comparison of the characteristics between D1_SPNs and D2_SPNs, characteristics of the LFPs at different degrees of isoflurane anesthesia, comparison of CNTs/PEDOT:PSS-modified MEAs, and the dynamic process of the quantitative dual-mode signal of isoflurane-induced death procedure (PDF)This article has not yet been cited by other publications.
chemistry, multidisciplinary, analytical,nanoscience & nanotechnology