Electrochemical DNA Sensors Based on MoS 2 -AuNPs for Polynucleotide Kinase Activity and Inhibition Assay
Meihua Lin,Hao Wan,Jian Zhang,Quan Wang,Xinyu Hu,Fan Xia
DOI: https://doi.org/10.1021/acsami.0c13385
2020-09-02
Abstract:The determination of T4 polynucleotide kinase (PNK) activity and the screening of PNK inhibitors are critical to disease diagnosis and drug discovery. Numerous electrochemical strategies have been developed for the sensitive measurement of PNK activity and inhibition. However, they often suffer from additional labels and multiple steps of the detection process for the electrochemical readout. Herein, we have demonstrated an electrochemical DNA (E-DNA) sensor for the one-step detection of PNK with "signal-on" readout with no need for additional labels. In our design, the highly switchable double-stranded DNA (dsDNA) probes are immobilized on the gold nanoparticle-decorated molybdenum disulfide nanomaterial (MoS<sub>2</sub>-AuNPs), which possesses large surface area and high conductivity for elevating the signal gain in the PNK detection. This signal-on E-DNA sensor integrated with MoS<sub>2</sub>-AuNPs exhibits a much higher sensitivity than that without MoS<sub>2</sub>-AuNPs, showing a detection limit of 2.18 × 10<sup>–4</sup> U/mL. Furthermore, this assay shows high selectivity, with the ability to discriminate PNK from other enzymes and proteins, and can be utilized to screen inhibitors. The proposed sensor is easy to operate with one-step readout and robust for PNK detection in the biological matrix and shows great potential for point-of-care in clinical diagnostics and drug screening.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acsami.0c13385?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acsami.0c13385</a>.Materials, instruments, the preparation process of nanomaterials; conformation and free energy of the secondary structure of DNA probes (Figure S1); zeta potential of MoS<sub>2</sub>-AuNP nanomaterials (Figure S2),; optimization of experimental conditions (Figure S3); stability of the MoS<sub>2</sub>-AuNP-based E-DNA sensor (Figures S4 and S5), Langmuir–Freundlich fitting (Figure S6), optimization, and sensitivity of the E-DNA sensor on the gold electrode surface (Figure S7); SWV peak current variation in buffer and cell lysates (Figure S6); comparison of different detection methods for PNK activity (Table S1); and calculation of the limit of detection (Table S2) (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c13385/suppl_file/am0c13385_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
materials science, multidisciplinary,nanoscience & nanotechnology