Characterization and Evaluation of a Recombinant Multiepitope Peptide Antigen MAG in the Serological Diagnosis of Toxoplasma Gondii Infection in Pigs

Yongle Song,Yongjuan Zhao,Ke Pan,Bang Shen,Rui Fang,Min Hu,Junlong Zhao,yanqin zhou
DOI: https://doi.org/10.21203/rs.3.rs-582733/v1
2021-01-01
Abstract:Abstract Background Toxoplasmosis caused by toxoplasma gondii (T. gondii) is a serious disease threatening human and animal health. People could be infected with T. gondii by ingesting raw pig meat contaminated with cysts or oocysts. Serological test is a sensitive and specific method usually used for large-scale diagnosis of T. gondii infection in humans and animals (such as pigs). Since commercial pig toxoplasma antibody ELISA diagnostic kits are too expensive, it is difficult to use them widely, moreover, the native antigen composition used in these diagnostic kits is still unclear and difficult to standardize. The multiepitope peptide antigen is novel diagnostic marker, and it has the potential to be developed into more accurate and inexpensive diagnostic kits. Methods The synthetic multiepitope antigen (MAG) gene encoding a protein with epitopes from 5 T. gondii dominant antigen (SAG1, GRA1, ROP2, GRA4, and MIC3) was designed, synthesized, and expressed in Escherichia coli BL21 (DE3) strain. The recombinant protein was detected through western blot with pig anti-T. gondii positive and negative serum, then IgG enzyme-linked immunosorbent assay (ELISA) named MAG-ELISA was designed. The MAG-ELISA was evaluated in terms of specificity, sensitivity, and stability. The MAG-ELISA was also compared with a commercial PrioCHECK® Toxoplasma Ab porcine ELISA (PrioCHECK ELISA). Finally, the trend of pig anti-T. gondii IgG level after artificially infection with RH tachyzoites was evaluated through MAG-ELISA and two other ELISA methods (rMIC3-ELISA and PrioCHECK ELISA). Results MAG antigen could be specifically recognized by pig anti-T. gondii positive but not negative serum. MAG-ELISA possessed a high diagnostic performance in terms of specificity and sensitivity. The overall coincidence rate between MAG-ELISA and a commercial PrioCHECK Toxoplasma antibody ELISA was 78.47%. MAG-ELISA could be used for detecting anti-T. gondii IgG in the early stage of T. gondii infection in pigs (at least 7 days after artificial infection). Conclusions Our results suggest that MAG antigen could be applied to specifically recognize anti-T. gondii IgG in pig, and MAG-ELISA has the potential for large-scale diagnosis of T. gondii infection in pig farms and intensive industries.
What problem does this paper attempt to address?