Performance Test of Regenerative Equipment with Solid-liquid Separation

Gong,Gong Shuyuan,Li Jinping,Peng Cao,Guo Jingtao,Huang Juanjuan
DOI: https://doi.org/10.46855/energy-proceedings-6448
2020-01-01
Abstract:In order to solve the problems of high heat loss, low fermentation temperature and low gas production in biogas engineering in winter.In this paper, the annual thermal energy loss of biogas project is systematically analyzed, and a regenerative mass recovery device with solid-liquid separation is developed.Finally, the heating effect of the device at different temperatures is tested through experiments.The results showed that under the condition of good heat preservation measures, the heat loss of the fermentation tank accounted for 89.3%  93.2% of the total heat loss of the anaerobic fermentation system.Under the ambient temperature of 18 ℃, the feed at 16.2 ℃can be heated to 26.6 ℃ by regeneration and mass recovery.The waste heat of the biogas slurry recovered accounted for 51.9% of the heat required for constant temperature fermentation.At ambient temperature of 0 ℃, the feed at 2.5 ℃ can be heated to 18.9 ℃ by regeneration and mass recovery.The waste heat of the biogas slurry recovered accounted for 47.2% of the heat required for constant temperature fermentation.The remaining heat is supplied by a collector array consisting of 14 groups of solar collectors, which can ensure the constant temperature fermentation of biogas engineering at 37 ℃ in winter.And the system has good economic and environmental benefits.
What problem does this paper attempt to address?