Abstract:In order to solve the problem of removing endocrine disruptors in water environment, Bi 2 WO 6 @MXenes-NS(BM-NS) composite catalyst was synthesized by hydrothermal method, and bisphenol A(BPA) was degraded by activation of permonosulfate(PMS). The morphology and crystal structure of the catalyst were characterized by SEM, TEM and XRD. The effects of different catalyst systems, PMS concentrations, solution pH and coexisting ions on the degradation of BPA were investigated. The results showed that when the concentration of MXenes-NS was 0.5%, the concentration of catalyst was 1 g/L, the concentration of PMS was 0.3 g/L, and the solution pH was 3.03, BM-NS/PMS system had a strong BPA degradation performance, and the removal rate reached 85.3% within 120 min. In addition, the effects of inorganic anions on BPA removal were in a sequence as follows: Cl - <H 2 PO - 4 <SO 2- 4 <HCO - 3 ≈NO - 3 . The removal rate of BPA remained 70.1% after 4 cycles. The results of the radical quenching experiment showed that SO - 4 · was the main active radical. Combined with LC-MS, the possible degradation pathway of BPA was proposed. The above experimental results indicated that the prepared BM-NS catalyst had a good application prospect in activating PMS to degrade BPA.