How Membrane Fouling Evolves During Electrodialysis Treatment of Cold-Rolling Wastewater?

Yinghua Li,Shijie Zhang,Jie Qian,Fei Su,Haibo Li
DOI: https://doi.org/10.5004/dwt.2023.29273
IF: 1.1
2023-01-01
Desalination and Water Treatment
Abstract:Membrane fouling is a serious concern in cold-rolling wastewater treatment using electrodialysis (ED). In this study, a commonly used anion exchange membrane was selected, and the evolution of fouling behavior was evaluated by contact angle, atomic force microscope (AFM), scanning electron microscope-energy-dispersive X-ray spectrometer (SEM-EDS), X-ray photoelectron spectroscopy (XPS) and attenuated total refraction-Fourier transform infrared (ATR-FTIR). Furthermore, mechanism of hybrid pollution by organic and inorganic contaminants was presented. Representative regeneration methods were carried out to investigate the removal of pollutants. The results showed that compared with the uncontaminated ED, the electrical resistance of desalination compartment increased by 5.49% and 10.42% after 48 and 96 h contamination, respectively. Meanwhile, Cl- recovery rate decreased from 64.33% +/- 0.02% (uncontaminated membrane) to 58.58% +/- 0.10% (contaminated for 48 h) and 55.32% +/- 0.52% (contaminated for 96 h). Results from SEM-EDS, AFM, XPS and FTIR revealed that the interaction between organic (dichloromethane, dichloroacetaldehyde, chloromethylsulfonyl chloride) and inorganic fouling (Fe2+) was the central factor in exacerbating membrane fouling, which resulted in more complicated fouling scenarios. It is recommended to remove chemical oxygen demand from membrane surface with 0.1% NaOH followed by 0.025% Na-SDS every 96 h to restore the permeability.