Early warning and diagnosis of primary fans based on improved MSET

YU Xing-gang,BIN Yi-yuan,CHEN Wen,WEI Xin,LIU Ming,QIU Bin-bin
DOI: https://doi.org/10.3969/j.issn.1001-4551.2023.04.009
2023-01-01
Abstract:Aiming at the problems of wind turbine fault early warning and fault point tracing in power station, a wind turbine fault early warning method based on improved multivariate state estimation technique(MSET)and error component was proposed. Firstly, the multivariate state estimation technology(MSET)was introduced. The modeling variables were selected, data preprocessing was performed, and the validity of model validity was verified by constructing an improved dynamic memory matrix D. Then, the similarity function was used as the basis for fault early warning, the sliding window method was used to reduce noise interference, and two kinds of dynamic memory matrix construction methods were used to build models and verify their effectiveness. Finally, the temperature and vibration fault data were simulated by artificially increasing the disturbance to carry out fault warning simulation, and the fault point was traced by calculating the error components of each parameter. The results show that the improved dynamic memory matrix modeling method has higher accuracy and stronger anti-interference ability. The improved MSET and error component model can successfully realize the early warning of faults and the traceability of fault points. This model can provide effective guidance for early warning and maintenance of power station equipment failures.
What problem does this paper attempt to address?