Experimental study of arrangement type on the reinforcement effect of electric geotextile-encased stone columns in soft soil

ZHANG Kang,ZHENG Ling-wei,ZHAO Tuan-zhi,XIE Xin-yu
DOI: https://doi.org/10.3785/j.issn.2096-7195.2023.02.003
2023-01-01
Abstract:To improve the bearing capacity of geosynthetic encased stone column(GESC) composite foundation, a combined method of electro-osmotic with electric geotextile as wrapping sleeve of GESC was proposed. Meanwhile, to explore the influence of the processing parameters in electro-osmosis combined with GESC on soft soil, indoor model tests at the laboratory scale with two types of electrode arrangement(line type and triangle type) were carried out. Three potential gradients(0.2 V/cm, 0.4 V/cm, 0.6 V/cm) were set for the line type arrangement, and the number of cathodes and anodes was set to 1∶2 and 2∶1 for the triangle type. The test results of drainage volume, electrified current, soil shear strength after the electro-osmotic process were obtained. The influence of the electric potential gradient and arrangement on the combined method was studied by analyzing the variation in the energy consumption coefficient and soil reinforcement mechanism. The results show that the energy consumption coefficient increases with increasing potential gradient. When the potential gradient is 0.2 V/cm, the overall energy consumption coefficient is low and the final discharge is large. So, it is not suitable to use a high potential gradient in engineering. The combined method has a good effect on the treatment of soil around the pile. The increase in the shear strength of the soil near the anode area is mainly caused by electro-osmosis and decays along the depth. The shear strength of the soil near the cathode area is mainly caused by the action of drainage water, and the closer to the drainage outlet, the better the reinforcement effect.
What problem does this paper attempt to address?