Effect of Microwave Digestion of Different Acid Systems on the Determination of Pb and Cd in PVC

An Huifang,Dang Zengchao,Yuan Huiwen,Zhao Yingfeng,Xue Tao,Liu Bin
DOI: https://doi.org/10.16525/j.cnki.cn14-1109/tq.2023.03.017
2023-01-01
Abstract:In this paper,four different acid systems were selected for microwave digestion of PVC,and the contents of Pb and Cd heavy metals in PVC were determined by inductively coupled plasma emission spectrometry (ICP-OES) to explore the effectiveness of different microwave digestion acid systems on the measurement results.The experimental results show that the HNO 3 +HBF 4 +H 2 O 2 mixed acid system-microwave digestion method achieves complete digestion of the sample,and the determination results of heavy metals are basically within the reference value range of the standard material.This method has the advantages of complete digestion,less pollution,high sensitivity and good repeatability,and can realize the rapid and accurate determination of Pb and Cd in PVC,which is worthy of further promotion and application.
What problem does this paper attempt to address?