Ultrasonic Testing of Defects in Pipeline Based on Image Characteristics of TOFD Circumferential Scan

JIN Shijie,ZHANG Bo,SUN Xu,WANG Zhicheng,LIN Li
DOI: https://doi.org/10.3901/jme.2023.04.018
2023-01-01
Journal of Mechanical Engineering
Abstract:When the ultrasonic time-of-flight diffraction(TOFD) circumferential scan is implemented on the pipeline, the propagation direction of the direct longitudinal wave(DLW) is not parallel to the pipeline surface. It is necessary to identify and locate the defects in the range above or below DLW. In particular, the range of the near-surface dead zone in TOFD is enhanced by pipe structure, and the defect diffracted wave is coupled with the DLW. In view of these problems, the characteristics of the diffracted waves in circumferential scan image are analyzed theoretically in polar coordinate, determining the relative position between flaw tips and DLW. On this basis, the defect beyond dead zone is located, and the depths of the defects in dead zone are obtained with the autoregressive spectral extrapolation method. The experimental results indicated that the upper surface slit with 4.0 mm depth and lower surface slit with 16.0 mm depth in the carbon steel pipeline with 30.0 mm thickness and 100.0 mm outer wall radius were located by using the TOFD probes with 5 MHz central frequency and different probe center separation(PCS). The measurement errors of slit depths were within 0.36 mm. The characteristics of diffracted waves are related to PCS, which should be adjusted reasonably for the TOFD circumferential scan of pipeline.
What problem does this paper attempt to address?