Optimization of ultrasonic tomography technology for concrete pile foundation

WANG Ke,WU Jun-tao,YU Zhe,XIANG Chi-xuan,WANG Kui-hua
DOI: https://doi.org/10.3785/j.issn.1008-973x.2023.04.018
2023-01-01
Abstract:The field source-point encryption technique based on the layout of the transducers, the scheme of reverse virtual ray path pair of omitting-receiving transducers, the improved SIRT algorithm considering the whole field correction, and the computed tomographic image post-processing technology, etc., were proposed respectively to improve the ultrasonic tomography effect of the RC pile foundations in view of the test characteristics of reinforced concrete(RC) pile foundation that the vertical dimension of cross-section area between two acoustic tubes is significantly larger than that of the horizontal dimension and the transducer spacing is relatively sparse. The ultrasonic tomography omitting and receiving transducer signals under different working conditions were simulated by using the finite element analysis software ABAQUS. Condition parameters that affect imaging effects were analyzed. Results show that it is quicker and more accurate to locate and quantify the potential defect among the cross-section area between two acoustic tubes by employing the proposed algorithms. The calculation reliability of the algorithm is high.
What problem does this paper attempt to address?