Endovascular Repair of Retrograde Stanford Type A Aortic Dissection with a New Stented Graft.

Jue Yang,Qiang Liu,Jinlin Wu,Jianfang Luo,Tucheng Sun,Changjiang Yu,Xin Li,Yucheng Peng,Yuan Liu,Yong Cao,Ruixin Fan
DOI: https://doi.org/10.1016/j.xjtc.2022.12.005
2023-01-01
JTCVS Techniques
Abstract:Central MessageWe have developed a new stented graft that can be used in Stanford type A aortic dissection; early results were satisfactory. We have developed a new stented graft that can be used in Stanford type A aortic dissection; early results were satisfactory. Stanford type A aortic dissection (TAAD) is a catastrophic aortic disease with high mortality rates.1Mussa F.F. Horton J.D. Moridzadeh R. Nicholson J. Trimarchi S. Eagle K.A. Acute aortic dissection and intramural hematoma: a systematic review.JAMA. 2016; 316: 754-763Crossref PubMed Scopus (307) Google Scholar Although many researchers have shown that open aortic replacement is effective for TAAD, these procedures must be performed with the assistance of deep hypothermic cardiac arrest and extracorporeal circulation and thus are complex and traumatic, as well as having a high rate of postoperative complications and mortality ranging from 10.3% to 24.2%.2Ehrlich M.P. Grabenwöger M. Kilo J. Kocher A.A. Grubhofer G. Lassnig A.M. et al.Surgical treatment of acute type A dissection: is rupture a risk factor?.Ann Thorac Surg. 2002; 73: 1843-1848Abstract Full Text Full Text PDF PubMed Scopus (14) Google Scholar,3Wang W. Duan W. Xue Y. Wang L. Liu J. Yu S. et al.Registry of Aortic Dissection in China Sino-RAD InvestigatorsClinical features of acute aortic dissection from the Registry of Aortic Dissection in China.J Thorac Cardiovasc Surg. 2014; 148: 2995-3000Abstract Full Text Full Text PDF PubMed Scopus (112) Google Scholar Thoracic endovascular aortic repair (TEVAR) has been demonstrated safe and effective in patients with thoracic aortic aneurysms and Stanford type B dissection.4Palma J.H. Almeida D.R. Carvalho A.C. Andrade J.C. Buffolo E. Surgical treatment of acute type B aortic dissection using an endoprosthesis (elephant trunk).Ann Thorac Surg. 1997; 63: 1081.e4Abstract Full Text Full Text PDF Scopus (58) Google Scholar However, there have been no commercial devices designed specifically for TAAD until now. We have developed a new stented graft that can be used in TAAD. The new stented graft (Shenzhen Chuangxin Medical Technology, Co, Ltd) consists of 3 segments: the proximal and distal end of the graft are covered stents, and the middle part is a bare metal stent (Figure 1). The bare stent is key to ensure the blood flow in the arch while maximizing the true lumen and promoting the closure and remodeling of the false lumen. This graft and the clinical trial were approved by the research ethics committee of Guangdong Provincial People's Hospital, and informed consent was obtained from these patients. The institutional review board number was QX2021-032-04, and the date of institutional review board approval was February 18, 2022. In the current study, we aim to report our early experiences with this novel graft. A 30-year-old man who presented with chest and back pain and dyspnea was admitted to our hospital with acute retrograde TAAD. Multidetector computed tomography revealed acute retrograde TAAD with a primary intimal tear located in the descending aorta and massive pleural effusion in the left side, which suggested the possibility of aortic rupture (Figure 2). Because of the possibility of aortic rupture, the mortality rate of conventional aortic replacement may be extremely high. Therefore, an endovascular approach was preferred. The size of the proximal graft equals to the sum of the true lumen and one half of the false lumen. Multidetector computed tomography image analysis is shown in Figure E1. To start with, a 6-F pigtail angiographic catheter was threaded through the left femoral artery into the left ventricle with segmental aortography to make sure the catheter was in the true lumen. A temporary pacemaker was placed through the right jugular vein. Then, a 5-F pigtail angiographic catheter was threaded through the right radial artery into the aortic sinus and thoracic aortography was performed (Figure E2). A 300-cm extra-stiff wire was placed into the left ventricle through the pigtail angiographic catheter. After that, the new stented graft was transferred to the ascending aorta via the extra-stiff wire and was released under temporary rapid pacing (140/min). Then a descending thoracic stent graft (34 × 30 × 190 mm; Shenzhen Chuangxin Medical Technology) was released to cover the primary intimal tear. Finally, thoracic aortography was performed again (Figure E3). The whole operative procedure is shown in Video 1. The operation time was 90 minutes, and the contrast medium volume was 115 mL. The patient was discharged uneventfully 8 days after the operation. The maximum false lumen in ascending aorta shrunk from 10 mm to 4 mm 1 month later (Figure E4). The primary treatment for TAAD is open surgery. However, patients with advanced age, poor general condition, or other comorbidities cannot tolerate these procedures. There are rapid technological advances in endovascular therapy providing new insights for the treatment of TAAD. The hybrid procedure takes advantage of openly surgical and TEVAR to reduce the damage. Total endovascular therapy may be the ultimate goal. The first endovascular repair of TAAD was reported by Dorros and colleagues5Dorros G. Dorros A.M. Planton S. O'Hair D. Zayed M. Transseptal guidewire stabilization facilitates stent-graft deployment for persistent proximal ascending aortic dissection.J Endovasc Ther. 2000; 7: 506-512Crossref PubMed Scopus (0) Google Scholar in 2000, in which only the ascending aorta was covered. Many challenges still exist for the application of TEVAR in the setting of TAAD, among which is the anatomically complex and functionally important branch of the arch. Techniques such as fenestrations and chimneys are only seen as transitional methods. We simplified the procedure by using a bare stent to cover the arch. The early results were satisfactory, and the middle- and long-term follow-up is ongoing. Recently, we have successfully performed endovascular repair in a DeBakey II aortic dissection with this new stented graft. We think it can be used in TAAD without intimal tears in aortic arch or lesions in aortic valve or orifices of coronary artery, which need more studies to confirm. eyJraWQiOiI4ZjUxYWNhY2IzYjhiNjNlNzFlYmIzYWFmYTU5NmZmYyIsImFsZyI6IlJTMjU2In0.eyJzdWIiOiI3NDc1NTY5NmU5YmIzMjJkYmY3ZGE4YTYyYjRhYjZkZSIsImtpZCI6IjhmNTFhY2FjYjNiOGI2M2U3MWViYjNhYWZhNTk2ZmZjIiwiZXhwIjoxNjk0ODQ3MDAyfQ.mTNc82EkuaOtp6PhXE9ok8WU1JP8nuZDRqPAkrrl1Gt9BglVRDI0YzXCctimMvaiM-2qjSCpZdTWuQuuVgdugdXsyMDkg2ho8G2Vwd6Qb3t8IO7dUMFf0UOqq2-w2V1Q6ANRnTuJwL1dVvyOMSJ4ivL3XNn5IrbW8UfEh9g6wVL0vYURuAG8UvesEgs7dKfhhzuwdez5LxrLtGjm-WLqAaTHNvcwNWU56VaXvXCq3FinWhFq5vbXTWt9fkQtX9Hb-ATdAKbNvGWuxeglrNKnRntsEuukH9PDjtAzpEOEks62G2-GapaCSgovcPX3JyQGD_cyyS-fCgF7CbW_0mwTfA Download .mp4 (22.7 MB) Help with .mp4 files Video 1Operative procedure of this case report. Step 1: A 6-F pigtail angiographic catheter was threaded through the left femoral artery into the left ventricle with segmental aortography to make sure the catheter was in the true lumen. Step 2: A 5-F pigtail angiographic catheter was threaded through the right radial artery into the aortic sinus and thoracic aortography was performed. A temporary pacemaker was placed through the right jugular vein. Step 3: A 300-cm extra-stiff wire was placed into the left ventricle through the pigtail angiographic catheter in the left ventricle. After that, the new stented graft was transferred to the ascending aorta via the extra-stiff wire. Step 4: Thoracic aortography was performed to make sure the stented graft in a suitable position. Then it was released under temporary rapid pacing (140/min). Thoracic aortography was performed again to observe position of stented graft and patency of aortic arch branch vessels. Step 5: A descending thoracic stent graft (34 × 30 × 190 mm; Shenzhen Chuangxin Medical Technology) was released to cover the primary intimal tear. Finally, thoracic aortography was performed to evaluate operative result. Video available at: https://www.jtcvs.org/article/S2666-2507(22)00601-0/fulltext. Download .jpg (.1 MB) Help with files Video 1Operative procedure of this case report. Step 1: A 6-F pigtail angiographic catheter was threaded through the left femoral artery into the left ventricle with segmental aortography to make sure the catheter was in the true lumen. Step 2: A 5-F pigtail angiographic catheter was threaded through the right radial artery into the aortic sinus and thoracic aortography was performed. A temporary pacemaker was placed through the right jugular vein. Step 3: A 300-cm extra-stiff wire was placed into the left ventricle through the pigtail angiographic catheter in the left ventricle. After that, the new stented graft was transferred to the ascending aorta via the extra-stiff wire. Step 4: Thoracic aortography was performed to make sure the stented graft in a suitable position. Then it was released under temporary rapid pacing (140/min). Thoracic aortography was performed again to observe position of stented graft and patency of aortic arch branch vessels. Step 5: A descending thoracic stent graft (34 × 30 × 190 mm; Shenzhen Chuangxin Medical Technology) was released to cover the primary intimal tear. Finally, thoracic aortography was performed to evaluate operative result. Video available at: https://www.jtcvs.org/article/S2666-2507(22)00601-0/fulltext. Figure E2Thoracic aortography before the stent graft was released.View Large Image Figure ViewerDownload Hi-res image Download (PPT)Figure E3Thoracic aortography after the stent graft was released.View Large Image Figure ViewerDownload Hi-res image Download (PPT)Figure E4A, Preoperative multidetector computed tomography. B, Multidetector computed tomography 1 month after surgery.View Large Image Figure ViewerDownload Hi-res image Download (PPT)
What problem does this paper attempt to address?