Cross-section and pore size regulation of hydroxyurea-modified polyacrylonitrile membrane by NH 2 -CNT and Si(OEt) 4 filler and heat treatment for dye removal application at medium temperature

Luo-lu Zhou,Yin-xin Fang,Jing Ye,Meng Chen,Hu Yang,Zhen-liang Xu
DOI: https://doi.org/10.1016/j.seppur.2023.124430
IF: 8.6
2023-06-29
Separation and Purification Technology
Abstract:The preparation of ultrafiltration (UF) membranes for dye removal at higher temperature is a challenging task. In this study, hydroxyurea-modified polyacrylonitrile (PAN-Hu) was used to prepare hydrophilic UF membrane. The further addition of NH 2 -grafted carbon nanotube (CNT) and tetraethoxysilane (TEOS) resulted in a change of the cross-section morphology of the membrane from half-sponge to an asymmetrical one, with an increased pore size due to the hydrophobic nature of the fillers. The resulting PHT/Si membrane showed a higher pure water flux (130 L/m 2 h at 1 bar) than PAN-Hu, with a 98% rejection rate of Congo red (CR) from a 0.1% NaCl aqueous solution. The dye rejection mechanism was explained based on the molecular size and surface charge density of dyes, as well as force analysis inside the spongy skin layer. Subsequently, two heating methods were adopted to stabilize the structure of membrane, and improve its thermal stability for filtration at medium temperature (60 °C). After heating in water at 60 °C for 5 days, the rejection rate of Methyl blue (MB) in a 0.1% NaCl solution increased by 80%, but the flux of membrane decreased by more than 50%. On the other hand, heating at 100 °C in glycerol for 10 hrs led to a similar increase in dye rejection but a lower decrease in flux. Specifically, the heated PHT/Si membrane showed a dye flux of 64 L/m 2 h, and an MB rejection rate of 94% from water, 80% from a 0.1% NaCl solution at 20 °C. Additionally, all membranes showed a higher flux and slightly lower rejection at 60 °C compared with that at 20 °C. Instrumental characterization revealed that morphology change of membrane was caused by the shrinkage effect through chain rearrangement as a result of heat treatment. But PAN-Hu showed a greater decrease in pore size than PHT/Si membrane. The reason lies in that CNT or SiO 2 in PHT/Si membrane acts as physical crosslinking point. Their dimension stabilization effect limits the free movement of polymer chains and affects the pore size change of membrane. Overall, this study can help to tailor the porous structure of UF membranes for dye removal under different temperatures.
engineering, chemical
What problem does this paper attempt to address?