Significant insights of Cu and Fe as key metals to cause RO membrane fouling under coal-mining wastewater treatment

Lequn Sun,Danyang Li,Weichen Lin,Kang Xiao,Daoyi Chen,Shuai Luo,Xia Huang
DOI: https://doi.org/10.1016/j.desal.2023.116517
IF: 11.211
2023-01-01
Desalination
Abstract:Membrane fouling for reverse osmosis (RO) was an annoying problem. Sufficient analysis was needed to reduce membrane fouling problem. Thus, this study used two fouled RO membranes in coal-mining wastewater to analyze metal impact. Greater percentage change of inorganic component (11.4 %) than organic component (2.6 %) on membrane surfaces indicated the importance of metals on membrane fouling, and the metals of Cu and Fe were found as the keystone metals to produce substances (EPS), including protein and polysaccharide (e.g., higher correlation factors at 0.686 and 0.619 for Cu and Fe than other metals). Sphingobacterium multivorum was selected as model bacteria to test the effect of key metals on membrane fouling. The result confirmed that Cu ion had highly inhibitory effect to reduce the bacterial density and Fe ion had stimulation effect on the EPS production and bacterial growth. FAPROTAX further confirmed the result that Cu could inhibit bacterial metabolism while Fe could stimulate EPS production. The value of this study was not only to know metal effect to cause RO fouling, but also create a routing protocol for engineers to follow to directly target the keystone metals in complex wastewater conditions to guide the engineers to solve the RO fouling problem.
What problem does this paper attempt to address?