Atomic Comagnetometer with a Closed-Loop Optically Aligned 87 Rb Dual-Frequency Oscillator

Zhiguo Wang,Xiang Peng,Zhiqiang Xiong,Jintao Zheng,Hui Luo,Hong Guo
DOI: https://doi.org/10.1103/physrevapplied.19.024021
IF: 4.6
2023-01-01
Physical Review Applied
Abstract:Comagnetometers have been widely used in fundamental research, such as tests of spin-gravity coupling and searches for permanent electric dipole moments (EDMs). Here, we report a comagnetometer that consists of simultaneous closed-loop oscillation of the F = 1 and F = 2 hyperfine Zeeman transitions of optically aligned 87Rb atoms. The Allan deviation of the F = 2 and F = 1 oscillation-frequency ratio reaches 1 x 10-9 after running continuously for 2 days, corresponding to a sensitivity of approximately 4 x 10-19 eV for the measurement of the hypothetical spin-dependent gravitational energy of the proton. The long-term stability of the comagnetometer can be further improved by system-level thermal control and optimization of the experimental parameters.
What problem does this paper attempt to address?