Performance Improvement of a 4 K GM/magnetic Hybrid Refrigerator with a New Magnetic Regenerator

Wenshuai Zheng,Jun Shen,Zhenxing Li,Xinqiang Gao,Ke Li,Hongmei Huang,Peng Hai,Zhaojun Mo,Wei Dai
DOI: https://doi.org/10.1016/j.applthermaleng.2023.120272
IF: 6.4
2023-01-01
Applied Thermal Engineering
Abstract:A hybrid refrigerator that combines the GM refrigeration effect with the magnetic refrigeration effect has been built before. Based on the hybrid refrigerator, a new magnetic regenerator filled with Pb, ErNi and EuTi0.875Al0.125O3 has been constructed to improve the cooling performance of the hybrid refrigerator. Among the three regenerative materials, EuTi0.875Al0.125O3 is a newly developed ferromagnetic material with high volumetric specific heat and large magnetocaloric effect below 5 K, which is better than the TmCuAl used in the previous regenerator. The numerical prediction shows that the new magnetic regenerator filled with EuTi0.875Al0.125O3 could obtain a lower cooling temperature and a larger cooling power in the hybrid refriger-ator. Then, the cooling performance of the new magnetic regenerator has been systematically studied by experimental tests. In the experiments, the minimum no-load temperature of the new magnetic regenerator could reach 2.48 K, which was much lower than the minimum no-load temperature of 3.5 K in the previous regen-erator. Meanwhile, the cooling power of 0.652 W at 4.2 K was produced in the new magnetic regenerator, which was larger than the previous regenerator by 0.361 W, and the corresponding relative Carnot efficiency was 0.48 % at 4.2 K in the new magnetic regenerator.
What problem does this paper attempt to address?