An Input-Output Regulated Adaptive Ramp for Fast Load Transition of PWM Buck Convertor.

Bingbing He,Haoran Li,Mingyi Chen,Yongfu Li,Yan Liu,Yang Zhao
DOI: https://doi.org/10.1109/ISCAS48785.2022.9937516
2022-01-01
Abstract:An input-output regulated adaptive ramp (IOR2) for fast load transition of pulse width modulation (PWM) buck convertor is presented. The scheme employs an adaptive ramp regulated by input and the voltage from the error amplifier to achieve fast load response and low line and load regulation rate. Simulation shows that an under/overshoot voltage of -32mV and 35mV, with 8 mu s and 8.3 mu s recovery time are respectively obtained for the load current stepping between 1A and 1.7A. The line/load regulation rate is respectively 12.4 mu V/V and 1.04mV/A. Implemented in a 0.25 mu m BCD process, the proposed IOR2 PWM regulator is capable of converting input voltage of 5V to 65V to output range of 3.3V to 60V with adjustable switching frequency up to 2.2MHz, showing a peak efficiency of 94.5% at 1A load current.
What problem does this paper attempt to address?