Calibration of magnetic gradient tensor system with differential evolution algorithm

Ding XueZhen,Li ZhuoXuan,Li YuGuo,Liu Hao
DOI: https://doi.org/10.6038/cjg2022P0611
2022-01-01
Abstract:For the non-orthogonality between axes, different scale factors and bias error of the single magnetic vector magnetometers and misalignment error of the magnetic gradient tensor system, we present a method for calibrating the magnetic gradient tensor system with improved differential evolution algorithm. Firstly, the above-mentioned errors are discussed in detail and the mathematical model is established. Then, the improved differential evolution algorithm is used to estimate the error parameters. The proposed method only needs to perform one-step inversion to realize the calibration of single-sensor system error and multi-sensor misalignment error. Two simulation examples are designed to verify the effectiveness of the proposed method. The simulation results show that, compared with the genetic algorithm and the least square fitting method, the proposed method has higher solution accuracy and search efficiency, and higher robustness against noise. The field test results show that after calibration, the measurement error caused by the system error can be reduced, and the measurement accuracy can be improved.
What problem does this paper attempt to address?