An Ingestible Self-Polymerizing System for Targeted Sampling of Gut Microbiota and Biomarkers

Lu Chen,Lina Gruzinskyte,Steffen Lynge Jørgensen,Anja Boisen,Sarvesh Kumar Srivastava
DOI: https://doi.org/10.1021/acsnano.0c05426
IF: 17.1
2020-08-24
ACS Nano
Abstract:A proof-of-concept for the fabrication of a self-polymerizing system for sampling of gut microbiome in the upper gastrointestinal (GI) tract is presented. An orally ingestible microdevice is loaded with the self-polymerizing reaction mixture to entrap gut microbiota and biomarkers. This polymerization reaction is activated in the aqueous environment, like fluids in the intestinal lumen, and causes site-specific microsampling in the gastrointestinal tract. The sampled microbiota and protein biomarkers can be isolated and analyzed <i>via</i> high-throughput multiomic analyses. The study utilizes a hollow microdevice (Su-8, <i>ca</i>. 250 μm), loaded with an on-board reaction mixture (iron chloride, ascorbic acid, and poly(ethylene glycol) diacrylate monomers) for diacrylate polymerization in the gut of an animal model. An enteric-coated rat capsule was used to orally gavage these microdevices in a rat model, thereby, protecting the microdevices in the stomach (pH 2), but releasing them in the intestine (pH 6.6). Upon capsule disintegration, the microdevices were released in the presence of luminal fluids (in the small intestine region), where iron chloride reacts with ascorbic acid, to initiate poly(ethylene glycol) diacrylate polymerization <i>via</i> a free radical mechanism. Upon retrieval of the microdevices, gut microbiota was found to be entrapped in the polymerized hydrogel matrix, and genomic content was analyzed <i>via</i> 16s rRNA amplicon sequencing. Herein, the results show that the bacterial composition recovered from the microdevices closely resemble the bacterial composition of the gut microenvironment to which the microdevice is exposed. Further, histological assessment showed no signs of local tissue inflammation or toxicity. This study lays a strong foundation for the development of untethered, non-invasive microsampling technologies in the gut and advances our understanding of host–gut microbiome interactions, leading to a better understanding of their commensal behavior and associated GI disease progression in the near future.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acsnano.0c05426?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acsnano.0c05426</a>.Video S1: Real-time hydrogel formation in multiple TRAP microdevices (<a class="ext-link" href="/doi/suppl/10.1021/acsnano.0c05426/suppl_file/nn0c05426_si_001.mp4">MP4</a>)Figure S1: SEM micrographs of activated TRAP microdevice. Figure S2: Confocal fluorescence microscopy image of enmeshed bacteria-hydrogel. Figure S3: Optical microscopy images and SEM micrographs of TRAP microdevices after animal experiment. Figure S4: Protein (trypsin) biomarker assessment. Figure S5: Rarefaction curves for samples 1–4. Figure S6: Heatmap of the 25 most abundant genera arranged with respect to sample 1 (gut tissue only). Table S1: Secondary index PCR data of samples 1–4 (<a class="ext-link" href="/doi/suppl/10.1021/acsnano.0c05426/suppl_file/nn0c05426_si_002.pdf">PDF</a>)This article has not yet been cited by other publications.
materials science, multidisciplinary,chemistry, physical,nanoscience & nanotechnology
What problem does this paper attempt to address?