Numerical Analysis of Inner Heating Tube Position for Improving Solid-Phase Transition in a Shell-and-tube Heat Accumulator

Gang Liu,Tian Xiao,Xinyi Wang,Xiaohu Yang,Hailong Li
DOI: https://doi.org/10.1016/j.aej.2022.10.022
2023-01-01
Abstract:Latent heat thermal storage (LHTS) system is vital to reduce environment pollution. In the shell-and-tube heat accumulator, the position of the inner heating tube plays a vital role in the thermal storage. To analyze the effect of the inner tube position on the phase transition, a twodimensional numerical model is developed. The structure has the minimum full melting time of 3480 s when the inner tube is 12 mm (L = 12 mm) from the center. Compared with L = 0 mm, the full melting time at L = 12 mm can be reduced by 13.4%.(c) 2022 THE AUTHORS. Published by Elsevier BV on behalf of Faculty of Engineering, Alexandria University. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
What problem does this paper attempt to address?