Intercalibration of FY-4A Agri Thermal Infrared Channels Against the AHI-8 Channels using the Double Difference Method.

Yi-Chun Xin,Geng-Ming Jiang,Yi-Zou
DOI: https://doi.org/10.1109/IGARSS46834.2022.9883426
2022-01-01
Abstract:This paper addresses the intercalibration of the thermal infrared channels 11 similar to 14 of the Advanced Geostationary Radiation Imager (AGRI) on the Chinese Fengyun 4A (FY-4A) satellite against the Advanced Himawari Imager on the Himawari 8 (AHI-8) using the Double Difference (DD) method, in which an accurate thermal infrared radiative transfer model is constructed over both sea and land surfaces. The intercalibration results indicate that the on-orbit radiometric calibration biases are observed in FY-4A AGRI thermal infrared channels, especially for the channel 11 (8.0 similar to 9.0 mu m), whose radiometric calibration biases are 4.36 +/- 0.26 K in the north hemisphere and 2.36 +/- 0.38 K in the south hemisphere. For the AGRI channels 12 (10.3 similar to 11.3 mu m), 13 (11.5 similar to 12.5 mu m) and 14 (13.2 similar to 13.8 mu m), the on-orbit radiometric calibration biases are -0.14 +/- 0.31 K, 0.91 +/- 0.41 K and -0.54 +/- 0.51 K, respectively. Through linear regression on the matching observations, the intercalibration coefficients are finally determined.