Design, experimental optimization, and flow analysis of a novel bioreactor for dynamic mammalian cell culture at laboratory scale using Box-Behnken design
Sepehr Govara,S.M. Hosseinalipour,Masoud Soleimani
DOI: https://doi.org/10.1016/j.cherd.2024.10.008
IF: 4.119
2024-10-11
Chemical Engineering Research and Design
Abstract:Highlights • A novel stirred bioreactor at a laboratory scale with a vibrating disc, a modified flask, and a simple set-up have been introduced. • Experimental quadratic models of cell growth indices based on structural factors of the bioreactor including the amplitude of vibration, the diameter of the disc, and the height of the disc from the flask bottom have been obtained using Box-Behnken design. • Effects of the main factors on the biological responses have been investigated and optimization of the bioreactor has been done. • Expressions for important dimensionless numbers of the fluid flow have been derived and flow analysis has been conducted based on these numbers. • The performance of the bioreactor has been compared with other common cell culture devices in laboratories based on the important indices of cell growth. Improving the quality of dynamic cell culture in laboratories is an important field in bioengineering. In this study, a novel lab-scale bioreactor using a vibrating agitator and a modified flask has been introduced to create a strong mixing at low shear stress. This bioreactor has been optimized using Box-Behnken design based on three dimensionless important structural factors including disc diameter, vibration amplitude, and the height of the disc placement. Three growth indicators including the specific growth rate, the natural logarithm of the maximum cell density, and productivity have been considered as biological responses. The results show that the disc diameter has the most important role in these indicators. If the disc diameter, vibration amplitude, and the height of disc placement are set to 0.24, 0.02, and 0.4 of the flask diameter, respectively, the values of the specific growth rate, the maximum cell density, and productivity at this optimum settings are 0.033 (h -1 ), 13.11, and 5133 (cells/(mL.h)), respectively. These values of the indicators are high and indicate the better performance of this bioreactor than other lab-scale bioreactors. In addition, investigating Reynolds number in the fluid flow indicates that in the range of 780 up to 1150, growth indices are high. Graphical abstract Download: Download high-res image (208KB) Download: Download full-size image
engineering, chemical