Self-reference photonic sampling measurement of photodiode chips with microwave de-embedding

Yutong He,Chao Jing,Mengke Wang,Ying Xu,Yali Zhang,Zhiyao Zhang,Shangjian Zhang,Yong Liu
DOI: https://doi.org/10.1117/12.2642304
2022-01-01
Abstract:An improved self-reference photonic sampling method is proposed to measure the frequency response of photodiode chips. In the proposed scheme, the uneven response of the mode-locked laser (MLL) is eliminated by using the half-frequency photonic sampling measurements. The microwave de-embedding under Short-Open-Load-Device termination is used to realize on-chip de-embedding of the adapter network connected to the receiver of the microwave network analyzer in terms of the transmission loss and the impedance mismatch. The proposed on-chip measurement method is free of any extra electro-optical transducer standard, and an accurate measurement can still be realized without an impedance match.
What problem does this paper attempt to address?