Diverse heating demands of a household based on occupant control behavior of individual heating equipment
Rongjiang Ma,Chunliu Mao,Xingli Ding,Mengsi Deng,Jill Baumgartner,Xianlin Wang,Xicheng Wang,Wei Yang,Huaican Liu,Ming Shan,Xudong Yang
DOI: https://doi.org/10.1016/j.enbuild.2019.109612
IF: 7.201
2020-01-01
Energy and Buildings
Abstract:The traditional design principle of household heating is based on full-space and continuous heating, which does not match the true heating demands of different functional spaces and thus leads to energy wastage. In this study, we used low-temperature air-to-air heat pumps (LTAAHPs) for space heating and studied the heating demands of six different rooms by testing the control behavior of occupants using heating equipment in a rural house in Beijing, China. The diverse heating demands of the six rooms were observed for 75 days (from January 12 to March 27, 2017) and verified using field measurements: (1) the utilization rates of the LTAAHPs differ; the mean rates range from 6.0% to 58.7%, indicating that heating is not required 41.3%–94.0% of the time; (2) the desired temperature settings differ, with average temperatures ranging from 20.3 to 25.7 ℃; (3) the power inputs per unit heating area differ, with average inputs ranging from 34.2 to 97.4 W/m2; and (4) the energy consumption per unit heating area differs, ranging from 6.7 to 37.3 kWh/m2. These results indicate that different rooms have different heating demands, although they belong to the same household. This study helps to understand actual heating demands while saving energy based on the proper control of individual heating equipment.
energy & fuels,construction & building technology,engineering, civil