Unconventional Application of Conventional Chromogenic Substrate Enables Unprecedented Dual-Mode Fluorescence and Colorimetric Detection of Peroxymonosulfat E

Haiyan Cao,Wenfei Dong,Wenbing Shi,Yuming Huang
DOI: https://doi.org/10.2139/ssrn.4162319
2022-01-01
Abstract:The extensive applications of peroxymonosulfate (PMS) in the field of environmental pollutant treatment based on advanced oxidation processes (AOPs) have prompted a high demand for advances in probe ranging from improving their performance to strengthening their practicality. Here, a simple, sensitive and highly selective assay of PMS achieved by traditional chromogenic substrate, 3,3',5,5'-tetramethylbenzidine (TMB), is described. An unprecedented dual-mode probe of PMS works on the Co 2+ -catalyzed specific conversion of TMB into chromogenic oxidation production (oxTMB) with PMS as the oxidizing agent, accompanied by the enhanced absorption values of oxTMB and decreased fluorescence intensity of TMB. The method enables us to determine PMS with the detection limit of 0.11 μM for UV-vis absorption spectrometry, and 0.03 μM for fluorescence spectrometry, respectively. In addition, the dose of Co 2+ in sensing system is as low as 5 μM, which is only one-four hundredth and one-tenth of the amount of spectrophotometry previously reported. Moreover, it exhibits good anti-jamming performance against other common substances in environmental samples. This study successfully proved a valuable strategy for sensing PMS, and verified the availability in dual-mode detecting the residual quantity of PMS in pollutant water treated by AOPs and PMS concentrations in actual water samples with peroxydisulfate (PDS).