Degradation of Hexafluoropropylene Oxide Tetrameric Acid (Hfpo-Tea) Using Electrocatalytic Ozone Technique

Zehong Yang,Shuting Guo,Xiaolin You,Qiongfang Zhuo,Bo Yang,Jiaming Huang,Junfeng Niu
DOI: https://doi.org/10.1016/j.watcyc.2022.08.001
2022-01-01
Water Cycle
Abstract:Hexafluoropropylene oxide tetrameric acid (HFPO-TeA) is an alternative to perfluorooctanecarboxylic acid (PFOA) and is commonly used in the production of perfluoropolymers. In this study, the performances of ozone oxidation, electrochemical oxidation, and electrocatalytic ozone techniques in the degradation of HFPO-TeA were compared. The experimental results indicated that the electrocatalytic ozone technique was best. The effects of different current densities, ozone concentrations, electrolyte types, and initial pollutant concentrations on HFPOTeA degradation were investigated. The results showed that the ratio of HFPO-TeA degradation reached 95.9% after electrolysis for 120 min for an initial HFPO-TeA concentration of 100 mg/L, a reaction volume of 120 mL, an applied current density of 10 mA/cm 2 , and an ozone concentration of 20 mg/L. The intermediate products detected were hexafluoropropylene oxide dimeric acid [C 3 F 7 OCF(CF 3 )COO - ], pentafluoropropionic acid [C 2 F 5 COO - ], and trifluoroacetic acid [CF 3 COO - ]. The mechanisms involved in HFPO-TeA degradation include direct electron transfer, indirect oxidation mediated by hydroxyl radicals ( & sdot;OH), and ozone oxidation.
What problem does this paper attempt to address?