Parametric Analysis on G-PV/T Collector: Performance Optimization and Energy Trade-off among Two Critical Structures under Various Outside Conditions

Zhaomeng Li,Jie Ji,Xudong Zhao,Guiqiang Li,Yu Cui,Zhiying Song,Tingting Yao
DOI: https://doi.org/10.1016/j.energy.2022.124449
IF: 9
2022-01-01
Energy
Abstract:The utilization potentiality of PV/T which laminates PV onto glass cover to improve reliability (G-PV/T) was proved previously, but how to optimize the structure is not comprehensive. This study focuses on its optimization and energy trade-off among two critical structural parameters (i.e., packing factor, air gap thickness). Firstly, mathematical models for G-PV/T are established and validated by the experimental data. Specifically, a special G-PV/T without air gap is also considered, and where its’ difference in optical models and heat transfer models are stated. Secondly, the past studies of PV/T used to investigate parametric optimization by discussing only one parameter at a time, but this study points out that the optimization methods for these structural parameters are interrelated, and their coupling relationship is influenced by outside conditions. So a matrix of the two parameters is used to predict the daily performance of G-PV/T and the results are presented in three-dimensional two-independent-variables plots, evaluated by the first and second laws of thermodynamics. Suggestions are given for structural optimization depending on application requirements and energy trade-off. Thirdly, performance under three important outside conditions is predicted to discuss how the system performance is influenced and how the coupling relationship of the two critical parameters moves.
What problem does this paper attempt to address?