Serum matrix metalloproteinase-7 for discriminating biliary atresia: a diagnostic accuracy and validation study
Jingying Jiang,Rui Dong,Min Du,Gong Chen,Jingyun Yang,Xinbao Xie,Yifan Yang,Weili Yan,Shan Zheng
DOI: https://doi.org/10.1186/s12967-024-05442-x
IF: 8.44
2024-07-08
Journal of Translational Medicine
Abstract:Abstract Background Prompt and precise differential diagnosis of biliary atresia (BA) among cholestatic patients is of great importance. Matrix metalloproteinase-7 (MMP-7) holds great promise as a diagnostic marker for BA. This study aimed to investigate the accuracy of age-specific serum MMP-7 for discriminating BA from other cholestatic pediatric patients. Methods This was a single center diagnostic accuracy and validation study including both retrospective and prospective cohorts. Serum MMP-7 concentrations were measured using an ELISA kit, the trajectory of which with age was investigated in a healthy infants cohort aged 0 to 365 days without hepatobiliary diseases ( n = 284). Clinical BA diagnosis was based on intraoperative cholangiography and subsequent histological examinations. The diagnostic accuracy of age-specific cutoffs of serum MMP-7 were assessed in a retrospective cohort of cholestatic patients ( n = 318, with 172 BA) and validated in a prospective cohort ( n = 687, including 395 BA). Results The MMP-7 concentration declines non-linearly with age, showing higher levels in healthy neonates as well as higher cutoff value in neonatal cholestasis. The area under the ROC curve (AUROC) was 0.967 (95% confidence interval [CI]: 0.946–0.988) for the retrospective cohort, and the cutoff of 18 ng/mL yielded 93.0% (95%CI: 88.1-96.3%), 93.8% (95%CI: 88.6-97.1%), 94.7% (95%CI: 90.1-97.5%), and 91.9% (95%CI: 86.4-95.8%) for sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), respectively. The performance of MMP-7 was successfully validated in the larger prospective cohort, resulting in a diagnostic sensitivity of 95.9% (379/395; 95% CI: 93.5–97.7%), a specificity of 87.3% (255/292; 95% CI: 83.0–90.9%), a PPV of 91.1% (379/416; 95% CI: 87.9–93.7%), and a NPV of 94.1% (255/271; 95% CI: 90.6–96.6%), respectively. Besides, higher cutoff value of 28.1 ng/mL achieved the best sensitivity, specificity, PPV, and NPV for infants aged 0–30 days, which was 86.4% (95% CI: 75.0–94.0%), 95.5% (95% CI: 77.2–99.9%), 98.1% (95% CI: 89.7–100%), and 72.4% (95% CI: 52.8–87.3%), respectively. Conclusions The serum MMP-7 is accurate and reliable in differentiating BA from non-BA cholestasis, showing its potential application in the diagnostic algorithm for BA and significant role in the future research regarding pathogenesis of BA.
medicine, research & experimental