Stretchable, Stable, and Degradable Silk Fibroin Enabled by Mesoscopic Doping for Finger Motion Triggered Color/Transmittance Adjustment
Zijie Xu,Wu Qiu,Xuwei Fan,Yating Shi,Hao Gong,Jiani Huang,Aniruddha Patil,Xuyi Li,Shutang Wang,Hongbin Lin,Chen Hou,Jizhong Zhao,Xing Guo,Yun Yang,Hezhi Lin,Lianfen Huang,Xiang Yang Liu,Wenxi Guo
DOI: https://doi.org/10.1021/acsnano.1c05257
IF: 17.1
2021-07-09
ACS Nano
Abstract:As a kind of biocompatible material with long history, silk fibroin is one of the ideal platforms for on-skin and implantable electronic devices, especially for self-powered systems. In this work, to solve the intrinsic brittleness as well as poor chemical stability of pure silk fibroin film, mesoscopic doping of regenerated silk fibroin is introduced to promote the secondary structure transformation, resulting in huge improvement in mechanical flexibility (∼250% stretchable and 1000 bending cycles) and chemical stability (endure 100 °C and 3–11 pH). Based on such doped silk film (SF), a flexible, stretchable and fully bioabsorbable triboelectric nanogenerator (TENG) is developed to harvest biomechanical energy in vitro or in vivo for intelligent wireless communication, for example, such TENG can be attached on the fingers to intelligently control the electrochromic function of rearview mirrors, in which the transmittance can be easily adjusted by changing contact force or area. This robust TENG shows great potential application in intelligent vehicle, smart home and health care systems.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acsnano.1c05257?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acsnano.1c05257</a>.The photograph of degradability test of composite SF and images of cell biocompatibility test based on SF-PU (4.2%)-Gl electrode (DOCX) The acid and alkali resistant test of composite SF electrode under pH 3, 7, and 11 (DOCX) The transmittance of the four different component electrode films at the range of 350–2000 nm (DOCX) The relationship between <i>V</i><sub>oc</sub> of SF-TENG with/without PU/Gl and the placing time in water (DOCX) The relationship between output voltage of SF-TENG and the bending cycles of composite SF electrode under a curve radius of 2 cm (DOCX) The relationship between <i>I<sub>sc</sub></i> of SF-TENG and the bending cycles of composite SF electrode under a curve radius of 2 cm (DOCX) The relationship between <i>V</i><sub>oc</sub> of SF-TENG and the placing time in 12 months (<a class="ext-link" href="/doi/suppl/10.1021/acsnano.1c05257/suppl_file/nn1c05257_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
materials science, multidisciplinary,chemistry, physical,nanoscience & nanotechnology