Preliminary Application of an Automated Acuity Detection System in Infant Visual Acuity Evaluation

文静,李晓清,杨必琨,崔锦实,王莉,曹奕雯,崔金玉,武一萍,陈巍,邢杉杉
DOI: https://doi.org/10.3760/cma.j.cn115909-20211227-00505
2022-01-01
Abstract:Objective::To explore the application of the automated acuity card procedure (AACP) developed by the Peking University First Hospital, the School of Electronics Engineering and Computer Science and the School of Psychological and Cognitive Sciences of Peking University.Methods::Prospective clinical study. From February 2018 to October 2021, using the AACP jointly developed by multiple colleges and departments of Peking University, children aged 5 months to 6 years old were tested automatically, and the Teller Acuity Card II (TAC-II) was used for manual detection at the same time. The results of the two tests were compared. The Wilcoxon sign rank test, Spearman rank correlation, and Bland-Altman plots were used to compare the differentiation, correlation and consistency between AACP and TAC-II.Results::All 33 children (66 eyes) aged 3-6 years completed the binocular visual acuity test of AACP and TAC-II. Among them, 30 children (54 eyes) completed the monocular visual acuity test of AACP and TAC-II. The completion rate of the binocular visual acuity test was 100%, and the completion rate of the monocular visual acuity test was 90.0%. Among 194 infants (388 eyes) aged 5-30 months, 141 infants (282 eyes) completed the binocular visual acuity test of the two methods and obtained effective data, with a completion rate of 72.7%. The AACP of 33 children aged 3-6 years was positively correlated with TAC-II binocular visual acuity and monocular visual acuity ( r=0.40, P=0.021; r=0.55, P<0.001). There was a strong correlation between AACP and TAC-II binocular vision in 141 infants aged 5-30 months ( r=0.88, P<0.001), and the correlation coefficient was higher than that of children aged 3-6 years, the Bland-Altman test showed 90.8 % points were all within the consistent range. There was a significant positive correlation between AACP and TAC-II visual acuity between different months of age ( r=0.82-0.94, all P<0.05), and there was a statistically significant difference in AACP visual acuity between different months of age ( H=32.02, P<0.001), with a trend that increased with age. Conclusion::There was a positive correlation between the visual acuity results obtained by the AACP and the TAC-II, especially with better results in young infants. The AACP is expected to become a useful tool suitable for clinical grating acuity evaluation and infant vision screening.
What problem does this paper attempt to address?