Mid-infrared Absorption Spectroscopic Sensor for Simultaneous and In-Situ Measurements of Ammonia, Water and Temperature

Yongbin Ji,Kun Duan,Zhimin Lu,Wei Ren
DOI: https://doi.org/10.1016/j.snb.2022.132574
2022-01-01
Abstract:A mid-infrared laser-based absorption sensor is developed for in-situ and simultaneous detection of ammonia, water and temperature for selective catalytic reduction (SCR) exhaust monitoring. The sensor used a quantum cascade laser (QCL) to target the NH3 line at 1103.45 cm-1 and a distributed-feedback (DFB) laser for H2O concentration and temperature by exploiting the line pair at 4029.52 cm-1 and 4029.78 cm-1. The time-division multiplexing (TDM) strategy was implemented to fulfill the H2O and temperature measurement with direct absorption spectroscopy (DAS) and the absolute concentration measurement of NH3 by calibration-free wave-length modulation spectroscopy (CF-WMS). All the experiments were conducted in a test chamber with a controlled temperature range of 296-673 K and pressure of 1 atm. The NH3 sensor was validated to achieve the detection limit of 7 ppb at the integration time of 100 s. The temperature measurement was also verified to show an uncertainty less than 3.5 %. We further performed the multi-parameter (NH3, H2O and temperature) mea-surement under the static condition and gas flowing condition, respectively. Our sensor successfully captured the time-varying species concentrations and temperature with a time resolution of 2.3 s, which is promising for SCR monitoring in terms of accuracy, sensitivity, and time response.
What problem does this paper attempt to address?