Optimization of Ventilation Performance of Side Air Supply for Large Indoor Spaces Using Deflectors and Slot Air Outlets

Haorui Wang,Junqi Wang,Zhuangbo Feng,Chuck Wah Yu,Shi-Jie Cao
DOI: https://doi.org/10.1177/1420326x221108587
2022-01-01
Abstract:Due to the large height and span of indoor spaces, efficient indoor ventilation performance may be difficult to achieve using the side air supply for large halls, to control the indoor air pollutants or reduce the infection risk, such as the transmission of COVID-19 within the breathing zone of occupants. An efficient Ventilation Mode with Deflector and Slot air outlets (VMDS) was developed by this study. The use of a deflector with slot air outlets was introduced by utilizing jet collision and adhesion effect to accentuate the ventilation performance of the side air supply for the large space. The numerical simulation model used in this study was validated experimentally. The VMDS was compared with three other side air supply modes used in large spaces, and the results were evaluated comprehensively. The results show that VMDS is effective in reducing indoor air pollutant concentrations and transmission of infectious diseases in large spaces while satisfying the energy efficiency and thermal comfort requirements. Compared with the common side-supply and side-return ventilation modes, VMDS can reduce indoor air pollutant concentration by nearly 40%, reduce the transmission risk of infectious disease to less than 1% at a low air change rate and increase the ventilation efficiency from about 0.85 to about 1.2. In addition, VMDS can theoretically reduce ventilation energy consumption by about 85%.
What problem does this paper attempt to address?