Fault Diagnosis Method of Smart Meters Based on DBN-CapsNet

Juan Zhou,Zonghuan Wu,Qiang Wang,Zhonghua Yu
DOI: https://doi.org/10.3390/electronics11101603
IF: 2.9
2022-01-01
Electronics
Abstract:Rapid and accurate fault diagnosis of smart meters can greatly improve the operational and maintenance ability of power systems. Focusing on the historical fault data information of smart meters, a fault diagnosis model of smart meters based on an improved capsule network (CapsNet) is proposed. First, we count the sample size of each fault type, and a mixed sampling method combining undersampling and oversampling is used to solve the problem of distribution imbalance of sample size. The one-hot encoding method is adopted to solve the problem of the fault samples containing more discrete and disordered data. Then, the strong adaptive feature extraction capability and nonlinear mapping capability of the deep belief network (DBN) are utilized to improve the single convolution layer feature extraction part of a traditional capsule network; DBN can also address the problem of high data dimensions and sparse data due to one-hot encoding. The important features and key information of the input sample are extracted and used as the input of the primary capsule layer, and the dynamic routing algorithm is used to construct the digital capsule. Finally, the results of experiments show that the improved capsule network model can effectively improve the accuracy of diagnosis and shorten the training time.
What problem does this paper attempt to address?