Design and Operation of Organic Rankine Cycles for Varied Power Load

Ran Li,Zhen Yang,Yuanyuan Duan
DOI: https://doi.org/10.1080/15435075.2022.2079948
IF: 3.206
2022-01-01
International Journal of Green Energy
Abstract:The organic Rankine cycles (ORC) always operate under off-design conditions due fluctuations in renewable energy access and actual user demand. Therefore, this study considered geothermal ORC as the research object to obtain the optimal design. The off-design performance was investigated under varied load curves by selecting different design loads. First, the optimal ORC system with a constant-rate load was obtained through minimizing the specific investment cost. For this optimal system, the exergy efficiency initially increased and then decreased under off-design operation conditions. Moreover, the peak efficiency was improved by increasing the design pressure. Second, the load curves of different users were considered, including industry, business, and residents. To achieve the best operational performance of the ORC for these varied load curves, different rate loads and pressures were selected, and then the off-design performance was studied. The results demonstrate that the rate load and maximum demand load are not optimal and that the optimal load ratio (rate load divided by the highest demand load) is 60%. The operating evaporation pressure obtained through the design is 1.9 MPa. For the optimal ORC, compared with a system with a load ratio of 1.0 (rate load is equal to the highest demand load), the total investment cost decreased by approximately 30.7%, and the average exergy efficiency increased by 19.2%.
What problem does this paper attempt to address?