Abstract:In this paper, the dynamical responses of methane/air flame in a micro-adjustable confined space to the external DC electric fields were evaluated experimentally. The effects of DC electric fields on several different flame characteristics while decreasing the combustion space were systematically measured and analyzed, including the flame stabilization, onset of flame with repetitive extinction and ignition(FREI), and global flame quenching. The results show that, the DC negative electric field can extend the stabilization limit of the flame, while the DC positive field will strengthen the oscillation of flame and destabilize the flame.The plausible mechanism was identified for the difference. For an FREI flame, both DC negative and positive electric field can accelerate the frequency by increasing the flame propagation speed due to the bidirectional ion wind enlarging the flame surface of the FREI flame. In addition, the quenching distance could be reduced by nearly 20% under the DC negative electric field . All results demonstrate the effectiveness of the DC electric field in achieving stable combustion in the micro confined space.Moreover, according to the measurements of temperature, chemiluminescence intensity, and flame shape, it can be concluded that the mechanism of the electric field affecting the flame behaviors is ionic wind.