Development and Validation of a Simple, Sensitive and Accurate LC‐MS/MS Method for the Determination of Guanfacine, a Selective Α2a‐adrenergicreceptor Agonist, in Plasma and Its Application to a Pharmacokinetic Study

Xiaonan Li,Ning Li,Xiaolin Sun,Wei Yang,Yu Dai,Jie Xu,Wei Zhang,Chunfeng Wang,Suilou Wang,Xijing Chen
DOI: https://doi.org/10.1002/bmc.2983
2013-01-01
Biomedical Chromatography
Abstract:ABSTRACT A simple, practical, accurate and sensitive liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and fully validated for the quantitation of guanfacine in beagle dog plasma. After protein precipitation by acetonitrile, the analytes were separated on a C 18 chromatographic column by methanol and water containing 0.1% (v/v) formic acid with a gradient elution. The subsequent detection utilized a mass spectrometry under positive ion mode with multiple reaction monitoring of guanfacine and enalaprilat (internal standard) at m / z 246.2 → 159.0 and m / z 349.2 → 205.9, respectively. Good linearity was obtained over the concentration range of 0.1–20 ng/mL for guanfacine in dog plasma and the lower limit of quantification of this method was 0.1 ng/mL. The intra‐ and inter‐day precisions were <10.8% relative standard deviation with an accuracy of 92.9–108.4%. The matrix effects ranged from 89.4 to 100.7% and extraction recoveries were >90%. Stability studies showed that both analytes were stable during sample preparation and analysis. The established method was successfully applied to an in vivo pharmacokinetic study in beagle dogs after a single oral dose of 4 mg guanfacine extended‐release tablets. Copyright © 2013 John Wiley & Sons, Ltd.
What problem does this paper attempt to address?