Observation and mitigation of image distortion in high-energy electron radiography
Hao-Qing Li,Liang Sheng,Chang-Qing Zhang,Ying-Chao Du,Zheng Zhou,Xiu-Feng Weng,Jia-Hao Xiao,Hong-Qiao Yin,Bin Sun,Kun Wei,Yang Li,Bao-Jun Duan,Yong-Tang Liu,Yan-Hong Zhang,Mei Zhang,Yan Song,Xiao-Dong Zhang,Jun Liu,Zhu-Ming Fu,Qing Xu,Xue Du,Jian-Peng Gao,Xin-Yi Wang,Xin-Jian Tan,Dong-Wei Hei
DOI: https://doi.org/10.1007/s41365-023-01234-y
2023-06-26
Nuclear Science and Techniques/Hewuli
Abstract:Image distortion caused by the angular misalignment of quadrupole magnets in high-energy electron radiography has been studied systematically. We propose that the distortion originates from the coupling of the electron motions in the transverse directions, based on a theoretical analysis and the transfer-matrix method. The relative angular rotation between the second and third magnetic quadrupoles was identified as the main contributor to image distortion. This was verified by both a beam-dynamics simulation and experiments. Different strategies to mitigate this image distortion are also explored, including magnets online tuning, higher beam energy and larger magnification factor. This study provides criteria for designing experiments and paves the way for achieving higher image precision.