Nanoparticle-assisted sacrificial synthesis of hierarchical porous carbon composite for rapid sample enrichment and ultrasensitive label-free immunosensing of interleukin-6 biomarker

Zhenping Liu,Qiuju Huang,Jiamei Chen,Jiyuan Yao,Mingliang Jin,Xin Wang,Eser Metin Akinoglu,Minmin Zhang,Na Li,Lingling Shui
DOI: https://doi.org/10.1016/j.jelechem.2021.115068
IF: 4.598
2021-02-01
Journal of Electroanalytical Chemistry
Abstract:<p>To achieve an ultrasensitive biosensor, the modified nanomaterials with high specific surface area, proper chemical and electrical/optical properties are highly required. In the present work, we designed a rapid and ultrasensitive label-free electrochemical immunosensor for interleukin-6 (IL-6) detection based on nanoporous mesoporous-carbon (NMC) composite decorated with gold nanoparticles (). The NMC served as the transducer matrix, which is modified on the surface of glassy carbon electrode (GCE), to deposit the gold nanoparticles (AuNPs). NMC is synthesized via a wrinkled SiO<sub>2</sub>-nanoparticle (<em>w</em>SiO<sub>2</sub>NP) assisted sacrificing strategy, which displays an interconnected 3D structure to achieve high specific surface area and abundant porous for rapid sample enrichment; meanwhile, the composited hierarchical porous structure promotes the deposition and entanglement of AuNPs to form stable and achieve enhanced electrical conductivity. Specific antibody against IL-6 protein is immobilized onto the surface of AuNPs, based on the antibody-antigen recognition strategy, the constructed immunosensors demonstrate high sensitivity and selectivity for assay of IL-6 with a linear dynamic range of 0.5–1200 pg·mL<sup>-1</sup> and the ultralow limit of detection (LOD) of 0.14 pg·mL<sup>-1</sup>. Toward the detection of IL-6 in human serum samples, this label-free biosensor with a short detection period (within 60 min, including sample processing and electrochemical measurement). Moreover, the label-free biosensor exhibited an excellent sensitivity and specificity, suggesting it possesses the potential for other biomarkers in point-of-care biosensing application.</p>
chemistry, analytical,electrochemistry
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a fast, ultrasensitive and label - free electrochemical immunosensor for the detection of the biomarker interleukin - 6 (IL - 6). Specifically, the research aims to achieve ultrasensitive detection of IL - 6 by designing and synthesizing nanomaterials with high specific surface area and appropriate chemical and electrical/optical properties. The solution proposed in the paper is based on the combination of nanoporous mesoporous carbon composite (NMC) and gold nanoparticles (AuNPs). This material can provide efficient sample enrichment and enhanced electrical conductivity, thereby improving the sensitivity and selectivity of the sensor. ### Main problems 1. **Improving detection sensitivity**: Traditional biosensors have the problem of insufficient sensitivity when detecting low - concentration biomarkers. In this paper, by designing the NMC@AuNPs composite with high specific surface area and rich pore structure, the sensitivity of the sensor is significantly improved. 2. **Shortening detection time**: Existing detection methods such as ELISA are time - consuming and are not suitable for rapid diagnosis. The sensor proposed in this paper can complete the whole process from sample processing to electrochemical measurement within 60 minutes. 3. **Improving selectivity and specificity**: In complex biological samples, selectivity and specificity are the keys to detecting specific targets. In this paper, through the antibody - antigen recognition strategy, highly selective and specific detection of IL - 6 is achieved. ### Solutions 1. **Material design**: Through the wrinkled SiO₂ nanoparticle - assisted sacrificial strategy, a nanocarbon material (NMC) with a hierarchical porous structure is synthesized. This material has a high specific surface area and rich pore structure, which is conducive to rapid sample enrichment. 2. **Electrode modification**: NMC is modified on the surface of the glassy carbon electrode (GCE), and gold nanoparticles (AuNPs) are deposited by electrodeposition method to form a stable NMC@AuNPs composite. 3. **Antibody immobilization**: The specific antibody against IL - 6 is immobilized on the surface of AuNPs, and the high - sensitivity and high - selectivity detection of IL - 6 is achieved by using the antibody - antigen recognition mechanism. ### Experimental results - **Linear range**: The linear range of the sensor for IL - 6 detection is from 0.5 to 1,200 pg/mL. - **Detection limit**: The lowest detection limit (LOD) is 0.14 pg/mL. - **Practical application**: Verification was carried out in human serum samples, and the results show that the sensor has good reproducibility, stability and specificity, and is suitable for point - of - care biosensing applications in clinical diagnosis. ### Conclusion In this paper, an electrochemical immunosensor based on the NMC@AuNPs composite is successfully developed. This sensor shows excellent sensitivity, selectivity and specificity in the detection of IL - 6 and has broad application prospects, especially in the early diagnosis of infectious diseases.