Millimeter-scale magnetic implants paired with a fully integrated wearable device for wireless biophysical and biochemical sensing

Ji Wan,Zhongyi Nie,Jie Xu,Zixuan Zhang,Shenglian Yao,Zehua Xiang,Xiang Lin,Yuxing Lu,Chen Xu,Pengcheng Zhao,Yiran Wang,Jingyan Zhang,Yaozheng Wang,Shaotong Zhang,Jinzhuo Wang,Weitao Man,Min Zhang,Mengdi Han
DOI: https://doi.org/10.1126/sciadv.adm9314
IF: 13.6
2024-03-21
Science Advances
Abstract:Implantable sensors can directly interface with various organs for precise evaluation of health status. However, extracting signals from such sensors mainly requires transcutaneous wires, integrated circuit chips, or cumbersome readout equipment, which increases the risks of infection, reduces biocompatibility, or limits portability. Here, we develop a set of millimeter-scale, chip-less, and battery-less magnetic implants paired with a fully integrated wearable device for measuring biophysical and biochemical signals. The wearable device can induce a large amplitude damped vibration of the magnetic implants and capture their subsequent motions wirelessly. These motions reflect the biophysical conditions surrounding the implants and the concentration of a specific biochemical depending on the surface modification. Experiments in rat models demonstrate the capabilities of measuring cerebrospinal fluid (CSF) viscosity, intracranial pressure, and CSF glucose levels. This miniaturized system opens the possibility for continuous, wireless monitoring of a wide range of biophysical and biochemical conditions within the living organism.
multidisciplinary sciences
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to achieve non - invasive and wireless biophysical and biochemical signal monitoring in vivo. Specifically, current implantable sensors mainly rely on wires passing through the skin, integrated circuit chips or bulky read - out devices to extract signals. These methods increase the risk of infection, reduce biocompatibility, or limit portability. To overcome these problems, researchers have developed a millimeter - scale, chip - free, battery - free magnetic implant, paired with a fully integrated wearable device, for wireless measurement of biophysical and biochemical signals. ### Main Problems 1. **Wireless Signal Transmission**: How to achieve wireless signal transmission between the implant and external devices and avoid infection and inflammation caused by wires. 2. **Miniaturization**: How to design miniaturized implants and wearable devices so that they are suitable for use outside hospitals or laboratories without the need for bulky instruments. 3. **Biocompatibility**: How to improve the biocompatibility of implants and reduce the impact on surrounding tissues. 4. **Multifunctional Sensing**: How to achieve synchronous monitoring of multiple biophysical and biochemical parameters, such as cerebrospinal fluid (CSF) viscosity, intracranial pressure (ICP) and CSF glucose levels. ### Solutions 1. **Magnetic Implant**: A millimeter - scale magnetic implant was designed, which contains micro - magnets, elastic membranes and surface coatings. The micro - magnets generate a dynamic magnetic field when vibrating, the elastic membranes increase the vibration amplitude, and the surface coatings can selectively adsorb target biomolecules. 2. **Wearable Device**: A centimeter - scale fully integrated wearable device was developed, which contains copper coils, tunnel magnetoresistance (TMR) sensors, Hall sensors, Bluetooth system - on - chip (SoC) and lithium - ion batteries. This device excites the vibration of the magnetic implant through a pulsed magnetic field and captures its subsequent movement. 3. **Wireless Communication**: The wearable device transmits data to mobile terminals via Bluetooth to achieve real - time display and further analysis. 4. **Multimodal Sensing**: Through different surface modifications, synchronous monitoring of multiple biophysical and biochemical parameters can be achieved. ### Experimental Verification - **Viscosity Measurement**: By changing the viscosity of the liquid environment, the relationship between the vibration attenuation rate of the magnetic implant and the viscosity was verified. - **Pressure Measurement**: By changing the external pressure, the relationship between the vibration frequency of the magnetic implant and the pressure was verified. - **Glucose Concentration Measurement**: Through surface modification, wireless detection of glucose concentration was achieved. - **In Vivo Experiment**: Experiments were carried out in a rat model to verify the biocompatibility and long - term monitoring ability of this system, and successfully measured cerebrospinal fluid viscosity, intracranial pressure and cerebrospinal fluid glucose levels. In conclusion, this paper proposes an innovative wireless sensing system, which solves the challenges of existing implantable sensors in wireless signal transmission, miniaturization, biocompatibility and multifunctional sensing.