Modeling Method of Heritage Chinese Timber Frames with Loose Mortise-Tenon Joints

Pan Yu,Qingshan Yang,Ke Liu
DOI: https://doi.org/10.1016/j.prostr.2022.01.141
2022-01-01
Procedia Structural Integrity
Abstract:Timber frame which commonly serves as the basic structural form in heritage Chinese timber buildings contains different types of semirigid joints such as loose mortise-tenon (MT) joints and free-standing column foot (CF) joints. The analytical models of MT and CF joints are introduced in this paper firstly. Next the hybrid finite elements with MT joint and CF joint are formulated for further modeling of the timber frame. Then a portal timber frame with MT and CF joints is taking as an example for illustration of the modeling method of heritage Chinese timber frame. The transverse behavior of the timber frame is further studied with distribution of the restoring moments at MT and CF joints at the three critical points. The reference may be provided based the obtained results for the preventive protection of heritage Chinese timber buildings.
What problem does this paper attempt to address?