Cooling performance analysis and structural parameter optimization of X-type truss array channel based on neural networks and genetic algorithm

Lei Xi,Liang Xu,Jianmin Gao,Zhen Zhao,Yunlong Li
DOI: https://doi.org/10.1016/j.ijheatmasstransfer.2021.122452
IF: 5.2
2022-01-01
International Journal of Heat and Mass Transfer
Abstract:This study aims to optimize the structural parameters of an innovative cooling channel filled with a novel X-type truss array structure, so as to improve the cooling performance of the mid-chord region of gas turbine blades. In this study, the design of experiment (DOE) for influence parameters of X-type truss array channels was carried out, the variation ranges of influence parameters are as follows: Reynolds number (ReH, 10,0 0 0 to 60,0 0 0), truss rod diameter ratio (d/H, 0.1 to 0.3), transverse spacing ratio (X-s/C, 0.1 to 0.3) and streamwise spacing ratio (Z(s)/C, 0.1 to 0.3). The comprehensive effects of each structural parameter and Reynolds number on the flow and heat transfer performance of X-type truss array channels were analyzed. Then the multi-input and multi-output neural network model with prediction deviations less than 3% for the X-type truss array channels was established. Finally, the optimal structure parameters and arrangement of the X-type truss array channels were obtained by optimization design based on the genetic algorithm method, and have been verified by experimental measurement. The results show that the average Nusselt numbers and the friction coefficients of the X-type truss array cooling channel both rise with increasing d/H, drop with increasing X-s/C, and first rise then drop with increasing Z(s)/C; the comprehensive thermal coefficients first rise and then drop with increasing d/H, X-s/C, and Z(s) /C . Based on the maximization of average Nusselt number, the optimal values of d/H and X-s /C are 0.3 and 1, the optimal values of Zs/C increase from 1.179 to 2.201, as ReH increases from 10,0 0 0 to 60,0 0 0. According to the optimization results of maximization of comprehensive thermal coefficient, the optimal values of d/H, Xs/C and Zs/C increase from 0.186 to 0.248, 1.696 to 2.482 and 1.0 to 1.945 respectively with increasing ReH. Compared with the reference channel, the average Nusselt number of the optimized X-type truss array channel increases by 44.50 to 145.49% and the comprehensive thermal coefficient increases by 4.16-9.56% at different Reynolds numbers. The results may provide new ideas for the design of internal cooling structure in future advanced gas turbine blades. (c) 2021 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?